Fundamental study on the effects of irreversible electroporation pulses on blood vessels with application to medical treatment
by Maor, Elad, Ph.D., UNIVERSITY OF CALIFORNIA, BERKELEY, 2009, 183 pages; 3426568

Abstract:

Background. Irreversible electroporation (IRE) is a biophysical phenomenon in which a series of electric field pulses selectively damages only the lipid bilayer of the cell membrane. This work is a fundamental study on the effect of IRE on blood vessels, evaluating the feasibility and efficiency of endovascular IRE to destroy vascular smooth muscle cells (VSMC) in the arterial wall.

Methods & Results. Time dependent finite-element simulations of the electric field and bio-heat transfer equations were used to analyze the electric field and the temporal behavior of the temperature due to electroporation pulses. The Henriques and Moritz thermal damage integral was used to demonstrate that an endovascular electrode geometry exists with which IRE pulses can be applied across the arterial wall with no thermal damage.

In-vitro experiments with VSMC compared different electroporation protocols in order to find the electric field threshold for efficient IRE. In-vivo experiments with rodents demonstrated for the first time that IRE can ablate the VSMC population of the arterial wall, and that the ablation persists at 28 days. By comparing eight different electroporation protocols it was demonstrated that best ablation efficiency can be achieved with 90 square direct current pulses of 100ìs at a frequency of 4 Hz delivering electric field of 1,750 V/cm across the vessel wall. In addition, a separate experiment demonstrated that IRE attenuated neointimal formation in rodent carotid arteries evaluated 28 days following angioplasty damage.

In-vivo experiments with New-Zealand white rabbits evaluated the use of endovascular IRE. Using custom made endovascular devices with four longitudinal electrodes on top of an inflatable balloon, IRE was successfully applied to the vessel walls of eight iliac arteries. Independent pathology analysis confirmed the efficient ablation of the VSMC population evaluated at 7 and 35. In-vivo experiment with the same animal model using angioplasty damaged iliac arteries, showed that endovascular IRE attenuated neointimal formation and luminal loss 35 days following angioplasty.

Conclusions. Non-thermal IRE is an efficient cell ablation method that can be used in an endovascular minimally-invasive approach. It holds the potential to treat multiple clinical problems, in particular the problem of coronary restenosis and cardiac arrhythmias.

 
AdviserBoris Rubinsky
SchoolUNIVERSITY OF CALIFORNIA, BERKELEY
SourceDAI/B 71-11, p. , Nov 2010
Source TypeDissertation
SubjectsBiomedical engineering; Electrical engineering; Medical Biophysics
Publication Number3426568
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:3426568
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.