Microfluidic detection of waterborne pathogen through light scattering of particle immunoassays
by Han, Jin-Hee, Ph.D., THE UNIVERSITY OF ARIZONA, 2008, 99 pages; 3326021

Abstract:

This dissertation focused on detecting waterborne pathogens in a microfluidic biosensing system which enables point-of-care, real-time monitoring. Within this framework, I have been addressing three objectives.

The first objective was to enhance mixing of particles in a microfluidic device. To this end, SDS (sodium dodecyl sulfate) or Tween 80 (polyethylene sorbitol ester) was added to the antibody-conjugated polystyrene microparticle suspension. Both surfactants showed non-specific binding (with SDS) or very poor diffusion (with Tween 80). As an alternative approach, highly carboxylated polystyrene microparticles showed very low non-specific binding comparable to that with Tween 80 and good diffusional mixing equivalent to that with SDS. This work was published in Appendix A (© 2008 Elsevier).

The second objective was to detect E. coli K-12 using the microfluidic-based system with low detection limit in Appendix B (© 2008 Elsevier). This method was essentially one-step and requires no sample pre-treatment or cell culturing. Conventional immunoassay using polyclonal antibody detects not only viable cells, but also dead cell and free antigens. In order to reduce false positive signal originated from dead cells and free antigens, target solution was washed three times. The detection limit was as low as 40 cfu ml-1 or 4 cfu per device (viable cells only), or <10 cfu ml-1 or <1 cfu per device (including dead cells and free antigens).

Our final objective was to develop real-time, high sensitive method for detecting waterborne pathogens in a water distribution system in Appendix C. Detection of Escherichia coli (E. coli) in a single straight pipe was demonstrated using a microfluidic 10 system utilizing light scattering detection of latex immunoagglutination assay. Assay time is <5 min per assay and detection limit is 10 cfu ml-1. Optical signals are compared with viable E. coli counts (not real time) and salt tracer experiments. Laminar (Re = 1,102) and turbulent (Re = 6,144) flows are used to simulate the flow regimes in a real water distribution system.

 
AdviserJeong-Yeol Yoon
SchoolTHE UNIVERSITY OF ARIZONA
SourceDAI/B 69-08, p. , Nov 2008
Source TypeDissertation
SubjectsAgriculture engineering; Biomedical engineering; Environmental engineering
Publication Number3326021
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:3326021
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.