Design and characterization of an electrohydrodynamic (EHD) micropump for cryogenic spot cooling applications
by Foroughi, Parisa, Ph.D., UNIVERSITY OF MARYLAND, COLLEGE PARK, 2008, 158 pages; 3312774

Abstract:

High-temperature superconducting (HTSC) components are being incorporated into communication and monitoring electronic devices to increase their signal-to-noise ratio or their channel capacity. Those devices must be maintained at cryogenic temperatures to prevent the loss of their superconducting properties and retain their performance superiority. They are conventionally cooled via direct heat conduction, which leads to undesirable temperature differences among the various components being cooled. Compact micropumps capable of pumping liquid nitrogen at 77 K into liquid-cooling circuits would enable a much more compact and lightweight method of maintaining a uniform temperature across the cooling circuit. These pumps can also address the demand for delivering small doses of LN2 to particular spots in bioengineering applications.

One of the main objectives of the present study was to develop an electrohydrodynamic (EHD) ion-drag micropump with LN2 as the working liquid. EHD ion-drag pumping phenomenon refers to liquid motion caused by an interaction between electric and hydrodynamic fields in a dielectric liquid.

To investigate the effect of each design parameter on the performance of the micropump, several prototypes with four distinct designs were fabricated and packaged. The designs included a variety of emitter shapes, inter-electrode spacings, electrode-pair spacings, and channel heights. The micropumps were tested at different DC voltages ranging from 0 to 2.5 kV. Two test rigs with novel measurement techniques were also designed, built, and calibrated to measure the generated static pressure head, electric current, and flow rate with an acceptable level of accuracy.

The relationships between pressure/current (P-I) and pressure/voltage (P-V) for various designs were investigated experimentally. The results showed good agreement with the general analytical trends reported for EHD pumping in the literature. The experimental results also demonstrated that electrode geometry and gaps are effective in determining the pressure onset voltage. The results also show that a maximum static pressure head of 160 Pa at 1400 V is achievable for a design with a combination of a 50-μm emitter-collector gap, a 200-μm electrode-pair gap, and a saw-tooth shaped emitter/flat collector.

 
AdviserMichael M. Ohadi
SchoolUNIVERSITY OF MARYLAND, COLLEGE PARK
SourceDAI/B 69-05, p. , Sep 2008
Source TypeDissertation
SubjectsPhysical chemistry; Mechanical engineering; Electromagnetics
Publication Number3312774
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:3312774
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.