Megasonic cleaning of wafers in electrolyte solutions: Possible role of electro-acoustic and cavitation effects
by Keswani, Manish, Ph.D., THE UNIVERSITY OF ARIZONA, 2008, 214 pages; 3297827

Abstract:

Megasonic cleaning is routinely used in the semiconductor industry to remove particulate contaminants from wafer and mask surfaces. Cleaning is achieved through proper choice of chemical solutions, power density and frequency of acoustic field. Considerable work has been done to increase understanding of particle removal mechanisms in megasonic cleaning using different solution chemistries with varying ionic strengths. However, to date, the focus of all these studies of particle removal has been either cavitation or acoustic streaming.

The propagation of sound waves through a colloidal dispersion containing ions is known to result in the generation of two types of oscillating electric potentials, namely, Ionic Vibration Potential (IVP) and Colloid Vibration Potential (CVP). These potentials and their associated electric fields can exert forces on charged particles adhered to a surface, resulting in their removal. In addition, the pressure amplitude of the sound wave is also altered in solutions of higher ionic strengths, which can affect the cavitation process and further aid in the removal of particles from surfaces. To test the two hypotheses, investigations have been conducted on the feasibility of removal of charged particles from silicon wafers in electrolyte solutions of different ionic strengths irradiated with a megasonic field of different power densities. Cleaning experiments have been performed using potassium chloride (KCl) as a model electrolyte and silica particles as model contaminant particles. The cleaning performance in KCl solution has been compared to that in other electrolytes solutions such as sodium chloride, cesium chloride and lithium chloride. In order to characterize the cavitation events in KCl solutions, acoustic pressure and sonoluminescence measurements have been performed using hydrophone and cavitation probe respectively. The results indicate that particle removal efficiency (PRE) increases with KCl concentration and transducer power density and much lower power densities are required at higher KCl concentration for a comparable level of cleaning. Further, cleaning performances in NaCl and CsCl were found to be superior to those in KCl and LiCl solutions. Theoretical computations show that the removal forces due to CVP are much larger in magnitude than those due to IVP and are comparable to van der Waals forces.

 
AdviserSrini Raghavan
SchoolTHE UNIVERSITY OF ARIZONA
SourceDAI/B 69-02, p. , Jun 2008
Source TypeDissertation
SubjectsChemical engineering; Materials Science; Acoustics
Publication Number3297827
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:3297827
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.