Simulated Cervical Acoustic Radiation Force Impulse (ARFI) Imaging
by Homyk, Andrew, M.S., DUKE UNIVERSITY, 2011, 57 pages; 1505072

Abstract:

Every day, 1,300 children in the U.S. and an additional 34,000 children worldwide are born prematurely. This study acts as a feasibility study for a proposed ultrasonic technique for the identification of preterm birth risk factors using an acoustic technique known as Acoustic Radiation Force Impulse (ARFI) imaging. A 3D finite element model was constructed to optimize transducer ARFI parameters in a layered cervix structure prior to clinical evaluation. The transducer model optimized in this study was the AcuNav™ (Siemens Medical Solutions, Mountain View, CA). Cervix model structural geometry and material properties were varied according to anticipated pregnancy induced property fluctuation. Transmitted ARFI acoustic fields were generated by applying a Field II derived pulse to the 3D model. Optimization procedures were performed in the following order: focal depth evaluation, transmit frequency optimization, effect of material property variation and the application of ARFI shear wave speed calculation algorithms to a layered cervical structure. Results indicated that ARFI evaluation of a layered cervix structure was most feasible using an 8MHz transmit frequency in the focal range of 5-10mm axial depth. It was observed that material property estimation errors were most likely when ARFI excitations were focused near a material boundary. A phenomenon was noted where shear waves initiated in stiffer media were slowed as a function of their relative proximity to a more compliant medium. Overall, these simulation studies demonstrate that ARFI shear wave imaging in the cervix is feasible; a model has been developed that can be used to evaluate the accuracy of shear stiffness estimates in the cervix to help address the important clinical problem of premature cervical ripening.

 
AdviserMark L. Palmeri
SchoolDUKE UNIVERSITY
SourceMAI/ 50-04, p. , Jan 2012
Source TypeThesis
SubjectsBiomedical engineering; Biomechanics
Publication Number1505072
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:1505072
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.