Abstract:

Supervisory control and data acquisition (SCADA) systems are used by many critical infrastructures including electric power production and distribution, water and waste water treatment, rail transportation, and gas and oil distribution. Originally isolated proprietary systems, SCADA systems are increasingly connected to enterprise networks and the Internet and today use commercial hardware and software. As a result SCADA systems now face serious cyber-security threats. The need for testing and evaluation of developed cyber-security solutions presents a challenge since evaluation on actual systems is usually not possible and building complete physical testbeds is costly. This thesis presents the design and development of a water systems simulation for testing and evaluation of cyber-security enhanced field devices.

The simulation consists of two main parts: a human machine interface/master terminal unit (HMI/MTU) component and a water treatment and distribution component. The HMI/MTU part supports new security protocols used to communicate with the hardened remote terminal unit (RTU). The water system simulates a water treatment and distribution center. A data acquisition (DAQ) module was used in conjunction with LabVIEW™ to create a water distribution and treatment simulation that could be interfaced with an actual field device. Field device I/Os are wired to the DAQ which then interface with the LabVIEWT™ simulation. The simulation supports: selectable polling of I/O, graphical representation of I/O, random water usage, constant water usage, and simulation data collection. The simulation uses a modular design pattern so that it can be easily extended in the future. Initial testing with a hardened RTU prototype confirmed the ability of the simulation to interact with real hardware and identified some minor errors in the prototype’s security protocol implementation. With additional DAQ devices the simulation could be extended to simulate larger water systems.

 
AdvisersJeffery L. Hieb; Rammahan K. Ragad
SchoolUNIVERSITY OF LOUISVILLE
SourceMAI/ 50-02, p. , Oct 2011
Source TypeThesis
SubjectsComputer engineering; Civil engineering; Electrical engineering; Computer science
Publication Number1504194
Adobe PDF Access the complete dissertation:
 

» Find an electronic copy at your library.
  Use the link below to access a full citation record of this graduate work:
  http://gateway.proquest.com/openurl%3furl_ver=Z39.88-2004%26res_dat=xri:pqdiss%26rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation%26rft_dat=xri:pqdiss:1504194
  If your library subscribes to the ProQuest Dissertations & Theses (PQDT) database, you may be entitled to a free electronic version of this graduate work. If not, you will have the option to purchase one, and access a 24 page preview for free (if available).

About ProQuest Dissertations & Theses
With over 2.3 million records, the ProQuest Dissertations & Theses (PQDT) database is the most comprehensive collection of dissertations and theses in the world. It is the database of record for graduate research.

The database includes citations of graduate works ranging from the first U.S. dissertation, accepted in 1861, to those accepted as recently as last semester. Of the 2.3 million graduate works included in the database, ProQuest offers more than 1.9 million in full text formats. Of those, over 860,000 are available in PDF format. More than 60,000 dissertations and theses are added to the database each year.

If you have questions, please feel free to visit the ProQuest Web site - http://www.proquest.com - or call ProQuest Hotline Customer Support at 1-800-521-3042.